*Closure Map
This allows you to change the relay assignments.
The Relay Specification section lists the different
functions and states. The names are listed in the
illustration to the right. The numbers are the relay
numbers. All six relays can be used if the time sync
and the alarm functions are not used. If they are
used, however, only the first four relays are
available. This section assumes that the alarm (#6)
and time sync (#5) functions are used and only
relays #1-#4 are available.
The Relay Test Menu is only accessible by holding
down the [UP] and [DOWN] at the same time while
in this menu.
General instructions:
1. [ENTER] moves between fields and accepts
changes
2. [BACK] goes to a previous field and saves the setting only when you are on the name of
the relay (P1LS, P1LE, etc.)
3. [UP] and [DOWN] change values
Changing settings:
1. Press [ENTER] to edit the closure map and highlight P1LS
2. Press [ENTER] to move to the relay – this will be 1 in the default settings
3. Press [UP] or [DOWN] to change this to any of the available relays (in the default
setting, only relays #1-#4 are available)
4. Press [ENTER] to move to the state – in the default settings, this will be ON
5. Press [UP] or [DOWN] to change the setting from ON to OFF or PULSE
6. Press [ENTER] to highlight P1LS
7. Press [BACK] to save your setting
Until you press [BACK] you will rotate through the NAME, RELAY and STATE.
To reset the closure map to its default settings, you must enter the Relay Test Menu
(pressing [UP] and [DOWN] at the same time) and then press [UP] and [DOWN] at the
same time while in the Relay Test Menu. The following section describes that procedure.
Rev. 36 – Firmware version 1.61 35
©
2008
Relay Test Menu - hidden
Closure Map
P2RS
P2RE
B2RS
B2RE
P1LS
P1LE
B1LS
B1LE
Vue de la page 34